M17/6-RG 12 (RG12A/U)

Construction

Inner conductor 

Tinned copper 

7 x 0.40 mm 

Dielectric 

Low density PE 

Φ7.25 ± 0.18 mm 

Outer conductor(shield 1) 

Plain copper 

192 x 0.18 mm 

Shield coverage 

97%

Inner sheath 

PVC 

Φ10.3 ± 0.18 mm 

Outer conductor(shield 2) 

Zinc-plated steel wire(FE-ZN) 

144 x 0.24 mm 

Shield coverage 

85%

Outer sheath 

PVC or LSZH 

Φ14.30 ± 0.20 mm 

Electrical & Mechanical Characteristics

Impedance 

75±5 Ohm 

Nominal capacitance 

67 pF/m 

Velocity of propagation 

66%

Insulation resistance 

>2000 Mohm.Km 

Inner conductor resistance 

20.5 Ohm/Km 

Outer conductor resistance 

4.5 Ohm/Km 

Test/Operatig Voltage(max) 

8.0 KV/5.0 KV 

Operating temperature range

 -30 °C - +70 °C 

Copper weight 

57 Kg/Km 

Cable weight (approx.) 

298.5 Kg/Km 

Screening effectiveness 

>70 dB 

Attenuation

Frequency(MHz)  

Attenuation (dB/100 m)  

Attenuation (dB/100ft)  

50 4.2 1.28

100

6.2

1.89

200

9.3

2.84

400

13.8

4.21

500

15.5

4.73

600

17.1

5.21

860

21.1

6.43

1000

23.4

7.13

Return Loss

30-300 MHz 

>30dB

300-600 MHz 

>27dB

600-900 MHz 

>25dB